ldentification of viruses, their viability and purification in drinking water

Abstract

This thesis aimed to identify viruses commonly found in water sources and assess the efficiency of water barriers in viral reduction at drinking water treatment plants (DWTPs) over time. Cell culture assays and molecular techniques were used to determine the inactivation of echovirus 30 (E30), simian rotavirus (RV SA11), and human adenovirus 2 (HAdV2) after treatment with chlorine, chlorine dioxide, and three different UV doses. All three viruses achieved a 3-4 log10 reduction after being disinfected by chlorine and chlorine dioxide. No virus was viable beyond 2 min of contact time by either chlorine or chlorine dioxide. The results suggested that the present CT (concentration x time) methods for lab-scale analysis might have an error. The UV dose of 400 J/m2 adequately inactivated E30 to 3 log10 reduction. However, 600 J/m2 was required to achieve a 3 log10 reduction of double-stranded viruses (RV SA11 and HAdV2). The viral identification in water samples from six DWTPs by next-generation sequencing (NGS) and later by qPCR revealed 147 classified viruses from 64 virus families and 6 unclassified viruses. Several viruses were identified in both raw and drinking water, although to a much lower degree, with a reduction of 1-3 log10. Virus removal by ultrafiltration increased proportionally with virus size, but other barriers such as rapid sand filtration appeared more effective at removing smaller viruses. The efficiency of some barriers was affected by factors such as temperature fluctuations, virus type, and different water sources.

Description

Keywords

DWTPs, Enteric virus, gastroenteric viruses, Drinking water

Citation

ISBN

978-91-8069-887-0 (TRYCK)
978-91-8069-888-7 (PDF)

Part of the series

Articles

I. Saguti, F., Churqui, M. P., Kjellberg, I., Wang, H., Ottoson, J., Paul, C., Bergstedt, O., Norder, H., Nyström, K. The UV Dose Used for Disinfection of Drinking Water in Sweden Inadequately Inactivates Enteric Virus with Double- Stranded Genomes. Int J Environ Res Public Health, 2022. 19(14). http://doi.org/10.3390/ijerph19148669

II. Saguti, F., Kjellberg, I., Churqui, M. P., Wang, H., Tunovic, T., Ottoson, J., Bergstedt, O., Norder, H., Nyström, K. The Virucidal Effect of the Chlorination of Water at the Initial Phase of Disinfection May Be Underestimated If Contact Time Calculations Are Used. Pathogens, 2023. 12(10). http://doi.org/10.3390/pathogens12101216

III. Saguti, F., Wang, H., Patzi Churqui, M., Tunovic, T., Holmer, L., Pettersson, Ä., Schleich. C., Bergstedt, O., Nyström, K., Norder, H., Variations of the virome in raw and treated water – a one-year follow-up at six different water treatment plants, manuscript, 2024.

IV. Saguti, F., Wang, H., Patzi Churqui, M., Tunovic, T., Holmer, L., Pettersson, Ä., Schleich. C., Bergstedt, O., Nyström, K., Norder, H., Highly efficient virus elimination at six Swedish drinking water treatment plants during one-year follow-up, manuscript, 2024

Department

Institute of Biomedicine. Department of Infectious Diseases

Defence location

Fredagen den 1 november 2024, kl. 9.00, Vån 3, Guldhedsgatan 10A, Göteborg

Opponent

Endorsement

Review

Supplemented By

Referenced By