• English
    • svenska
  • English 
    • English
    • svenska
  • Login
View Item 
  •   Home
  • Student essays / Studentuppsatser
  • Institute of Health and Care Sciences / Institutionen för vårdvetenskap och hälsa
  • Magisteruppsatser / Institutionen för vårdvetenskap och hälsa
  • View Item
  •   Home
  • Student essays / Studentuppsatser
  • Institute of Health and Care Sciences / Institutionen för vårdvetenskap och hälsa
  • Magisteruppsatser / Institutionen för vårdvetenskap och hälsa
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Blodtrycksmätning inom intensivvård. En kvantitativ observationsstudie

Blood pressure measurement in intensive care. A quantitative observational study

Abstract
Bakgrund: Att monitorera och bedöma blodtryck är vanligt förekommande inom intensivvård. Ett adekvat blodtryck är av stor vikt för den kritiskt sjuka patienten och intensivvårdssjuksköterskan är ansvarig för att monitorera och vidta åtgärder för att uppnå ett adekvat blodtryck. Tidigare forskning visar att det finns skillnader i blodtryck uppmätt med invasiv och icke-invasiv mätmetod. Hur dessa skillnader påverkas av patientens olika kroppspositioner är dock mindre studerat. Syfte: Syftet var att undersöka skillnader i blodtryck uppmätt med invasiv och icke-invasiv mätmetod i olika kroppspositioner på patienter inom intensivvård. Metod: En kvantitativ, deskriptiv observationsstudie. Datainsamlingen utfördes genom blodtrycksmätningar med invasiv och icke-invasiv mätmetod vid två intensivvårdsavdelningar. Dataanalys genomfördes med Bland-Altman plot för att undersöka skillnader mellan mätmetoderna. Resultat: I resultatet framkommer att det finns skillnader i medelartärtryck uppmätt med invasiv och icke-invasiv mätmetod och att medelartärtryck uppmätt med icke-invasiv mätmetod generellt var högre. I resultatet framkommer också att det finns skillnad mellan medelartärtryck uppmätt med invasiv och icke-invasiv mätmetod vid sidoläge. I resultatet framkommer även att fler medelartärtryck under ordinerat målvärde uppmättes med invasiv mätmetod jämfört med icke-invasiv mätmetod. Slutsats: Intensivvårdssjuksköterskan behöver i sin bedömning av blodtryck vara medveten om att medelartärtryck kan variera beroende på vilken mätmetod som används. Större studier behövs dock för att undersöka skillnader i medelartärtryck uppmätt i sidoläge för att utveckla riktlinjer som stödjer intensivvårdssjuksköterskan vid kliniska bedömningar av blodtryck.
Degree
Student essay
Other description
Background: Monitoring and assessing blood pressure is a common practice in intensive care. Maintaining adequate blood pressure is crucial for critically ill patients, and the critical care nurse is responsible for monitoring and taking actions to achieve adequate blood pressure. Previous research shows that there are differences in blood pressure measured with invasive and non-invasive methods. However, how these differences are affected by the patient's various body positions is less studied. Aim: The aim was to investigate differences in blood pressure measured with invasive and non-invasive methods in different body positions in intensive care patients. Method: A quantitative, descriptive observational study. Data collection was carried out through blood pressure measurements using invasive and non-invasive methods in two intensive care units. Data analysis was performed using Bland-Altman plots to evaluate differences between the measurement methods. Results: The results show that there are differences in mean arterial pressure measured with invasive and non-invasive methods, and that mean arterial pressure measured with non-invasive methods was generally higher. The results also show that there is a difference in mean arterial pressure measured with invasive and non-invasive methods in the lateral position. Additionally, more mean arterial pressures below the prescribed target value were measured with the invasive method compared to the non-invasive method. Conclusion: The critical care nurse needs to be aware that mean arterial pressure can vary depending on the measurement method used. Larger studies are needed to investigate differences in mean arterial pressure measured in the lateral position to develop guidelines that support the critical care nurse in clinical assessments of blood pressure.
URI
https://hdl.handle.net/2077/86481
Collections
  • Magisteruppsatser / Institutionen för vårdvetenskap och hälsa
View/Open
OM5330.SAE.RW.TL.V25.pdf (1.701Mb)
Date
2025-04-16
Author
Anderius Eliasson, Sebastian
Löfberg, Tobias
Wiberg, Robin
Keywords
Blodtryck
icke-invasiv mätmetod
intensivvård
intensivvårdssjuksköterska
invasiv mätmetod
kliniska bedömningar
medelartärtryck
Language
swe
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV