Show simple item record

dc.contributor.authorAxelsson, Peter Axelsson
dc.date.accessioned2018-01-30T13:01:20Z
dc.date.available2018-01-30T13:01:20Z
dc.date.issued2018-01-30
dc.identifier.isbn978-91-629-0390-9 (Print)
dc.identifier.isbn978-91-629-0390-6 (Pdf)
dc.identifier.otherhttp://hdl.handle.net/2077/54529
dc.identifier.urihttp://hdl.handle.net/2077/54529
dc.description.abstractThe growing interest in distal radioulnar (DRUJ) disorders underlines the need for further improved evaluations of treatment outcome. Load-bearing and optimising torque are important features of the DRUJ, but they are rarely measured when assessing DRUJ interventions. To make these measurements easily accessible in clinical situations, we developed two methods for quantifying lifting strength and forearm torque. In this thesis, we report the outcomes after surgery with two types of DRUJ implant arthroplasty and the result of our evaluation of the new strength measurement methods. In Study I, we reviewed 21 patients treated with the Herbert ulnar head prosthesis and, in Study II, we included nine patients treated with the Scheker total DRUJ prosthesis after previously failed DRUJ surgery. For both types of arthroplasty, the patient-reported outcome was satisfactory, scores for pain were low and there were no signs of radiographic loosening. There was one re-operation (Herbert prosthesis), but no other major complications. In Study III, we assessed the reliability and validity of our methods in quantifying lifting strength and forearm torque. Intraclass correlation coefficient calculations showed that the inter- and intrarater reliability was excellent and the new methods were also valid when the Baltimore Test Equipment was used as a reference. In Study IV, we measured 499 healthy volunteers to obtain normal values for our new test methods. Normative data were defined and we were able to compute predictive equations based on gender, age and height. In Study V, we evaluated the responsiveness and validity of the new strength measurement methods in 18 patients treated with DRUJ implant arthroplasty. We found that forearm torque was more sensitive to change than grip strength. Forearm torque also had a stronger correlation to the other outcome variables. In conclusion, it was confirmed that the Herbert and Scheker implants are efficient and safe, in the mid-term perspective, in a selected group of patients. Our methods for measuring strength for lifting and forearm rotation were reliable and valid and normative values were defined. Forearm torque outperformed grip strength in the evaluation of DRUJ implant arthroplasty.sv
dc.language.isoengsv
dc.relation.haspartAxelsson P, Sollerman C, Karrholm J. Ulnar Head Replacement: 21 Cases; Mean Follow-Up, 7.5 Years. J Hand Surg Am. 2015;40(9):1731-1738. ::doi::10.1016/j.jhsa.2015.06.100sv
dc.relation.haspartAxelsson P, Sollerman C. Constrained implant arthroplasty as a secondary procedure at the distal radioulnar joint: early outcomes. J Hand Surg Am. 2013;38(6):1111-1118. ::DOI::10.1016/j.jhsa.2013.03.030sv
dc.relation.haspartAxelsson P, Karrholm J. New methods to assess forearm torque and lifting strength: reliability and validity. (In press, J Hand Surg Am.)sv
dc.relation.haspartAxelsson P, Fredrikson P, Nilsson A, Andersson JK, Karrholm J. Forearm torque and lifting strength: normative data. (In press, J Hand Surg, Am.)sv
dc.relation.haspartAxelsson P, Sollerman C, Karrholm J. Validity and responsiveness of forearm strength measurements in the evaluation of distal radioulnar joint implant arthroplasty. (In manuscript)sv
dc.subjectDistal Radioulnar joint arthroplastysv
dc.subjectForearm torque and lifting strength measurementssv
dc.subjectNormative datasv
dc.subjectReliabilitysv
dc.subjectValiditysv
dc.subjectResponsivenesssv
dc.titleDistal radioulnar joint: arthroplasty and strength assessmentssv
dc.typetexteng
dc.type.svepDoctoral thesiseng
dc.gup.mailpeter.axelsson@vgregion.sesv
dc.type.degreeDoctor of Philosophy (Medicine)sv
dc.gup.originUniversity of Gothenburg. Sahlgrenska Academysv
dc.gup.departmentInstitute of Clinical Sciences. Department of Orthopaedicssv
dc.gup.defenceplaceFredagen den 2 mars, kl. 13.00, Hörsal Arvid Carlsson, Academicum, Medicinaregatan 3, Göteborgsv
dc.gup.defencedate2018-03-02
dc.gup.dissdb-fakultetSA


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record