Provtagningseffektivitet för den svenska metoden för mätning av totaldamm
Abstract
The open-face 37 mm filter cassette used in Sweden as a sampler for total dust has been tested in a wind-tunnel, with cassettes mounted on a mannequin. The experiments show that the total dust sampler does not sample all airborne particles. Neither follows the sampling efficiency of the filter cassette the sampling convention for inhalable dust. The filter cassette has (for wind speeds in the range 0.5-1 m/s) a sampling efficiency which decreases with increasing particle size (with 50% sampling efficiency occurring at 27 µm). For particle sizes larger than 47 µm the sampling efficiency has a constant value, equal to 12%. The low sampling efficiency of the total dust sampler entails that it should not be used for the sampling of generally toxic substances, or aerosols deleterious to the head airways. Den filterkassett som i Sverige används för provtagning av totaldamm har testats i en vindtunnel, monterad en provdocka. Experimenten visar att totaldammkassetten ej provtar allt luftburet damm. Totaldammkassettens provtagningseffektivitet följer inte ens provtagningskonventionen för inhalerbart damm. Totaldammkassetten har (vid vindstyrkor 0,5-1 m/s) en med partikelstorleken minskande provtagningseffektivitet (50% effektivitet vid 27 µm), för att bli konstant lika med 12% för partikelstorlekar större än 47 µm. Totaldammkassettens låga effektivitet för stora partiklar medför att den ej bör användas vid provtagning av aerosoler vilka är systemtoxiska eller skadliga för huvudets andningsvägar.
Publisher
Arbetslivsinstitutet
Collections
View/ Open
Date
1997Author
Lidén, G
Kenny, L
Mark, D
C Chalmers
Publication type
report
ISBN
91-7045-419-1
ISSN
0346-7821
Series/Report no.
Arbete och Hälsa 1997:13
Language
swe