GUPEA >
Sahlgrenska Academy / Sahlgrenska akademin >
Institute of Odontology / Institutionen för odontologi >
Doctoral Theses / Doktorsavhandlingar Institutionen för odontologi >

Radiographic follow-up analysis of Brånemark® dental implants


Please use this identifier to cite or link to this item: http://hdl.handle.net/2077/10124

Files in This Item:

File Description SizeFormat
Ramen.pdfThesis frame3775KbAdobe PDF
View/Open
Spikblad.pdfAbstract111KbAdobe PDF
View/Open
Title: Radiographic follow-up analysis of Brånemark® dental implants
Authors: Sundén Pikner, Solweig
E-mail: solweig1@tele2.se
Issue Date: 15-May-2008
University: University of Gothenburg. Sahlgrenska Academy
Institution: Inst of Odontology. Dept of Oral and Maxillofacial Radiology
Parts of work: I. Sundén S, Gröndahl K, Gröndahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants. Clin Oral Implants Res 1995; 6: 220-226.
VIEW ARTICLE


II. Gröndahl K, Sundén S, Gröndahl HG. Inter- and intraobserver variability in radiographic bone level assessment at Brånemark fixtures. Clin Oral Implants Res 1998; 9: 243-50
VIEW ARTICLE


III. Sundén Pikner S, Gröndahl K, Jemt T, Friberg B. Marginal bone loss at implants: a retrospective, long-term follow-up of turned Brånemark System® implants. Clin Implant Dent Relat Res, accepted for publication

IV. Sundén Pikner S, Gröndahl K. Radiographic analyses of “advanced“ marginal bone loss around Brånemark® dental implants. Clin Implant Dent Related Res, accepted for publication.
Disputation: Onsdagen den 4 juni 2008, kl. 9.00, i föreläsningssal 3, institutionen för odontologi, Medicinaregatan 12D, Göteborg
Degree: Doctor of Philosophy (Odontology)
Publication type: Doctoral thesis
Keywords: Cluster effect
Dental implants
Dependency
Diagnostic accuracy
Long-term follow-up
Marginal bone level
Observer variation
Osseointegration
Prediction
Abstract: Radiography plays an important role in clinical routine practice and in research projects evaluating dental implants, among them Brånemark® System. Presence of a peri-implant radiolucency has been used in studies as a criterion for implant failure without knowledge of its diagnostic accuracy. More precise determination, whether implants are osseointegrated or not, can be achieved if prosthetic constructions are detached to test implant stability. Such an approach is time-consuming and cumbersome... more
ISBN: 978-91-628-7411-7
ISSN: 0348-6672
URI: http://hdl.handle.net/2077/10124
Appears in Collections:Doctoral Theses from Sahlgrenska Academy
Doctoral Theses / Doktorsavhandlingar Institutionen för odontologi
Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet

This item has been viewed 444 times.

 

 

© Göteborgs universitet 2011