<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T09:30:37Z</responseDate><request verb="GetRecord" identifier="oai:gupea.ub.gu.se:2077/7617" metadataPrefix="dim">https://gupea.ub.gu.se/server/oai/request</request><GetRecord><record><header><identifier>oai:gupea.ub.gu.se:2077/7617</identifier><datestamp>2013-04-23T15:06:03Z</datestamp><setSpec>com_2077_284</setSpec><setSpec>com_2077_17</setSpec><setSpec>com_2077_10556</setSpec><setSpec>col_2077_305</setSpec><setSpec>col_2077_310</setSpec><setSpec>col_2077_10557</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Östman, Pär-Olov</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-11-30T08:54:22Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-11-30T08:54:22Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2007-11-30T08:54:22Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="isbn">978-91-628-7346-2</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/2077/7617</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Backgrund: Prosthetic rehabilitation of the edentulous patient with implant-supported bridges is today a routine&#xd;
and predictable treatment modality. The original protocol prescribed a healing period of 3 to 6 months prior to&#xd;
loading which means that the total treatment time can be extensive and that the patients often need to wear removable&#xd;
provisional prostheses during healing and treatment. The use of immediate implant loading protocols&#xd;
would significantly reduce treatment time.&#xd;
Aims: The aim of this thesis was to clinically and radiographically evaluate different protocols for immediate&#xd;
loading of dental implants with regard to implant survival and marginal bone resorption.&#xd;
Material &amp;amp; Methods: Paper I. The use of provisional implants (PIs) for support of a fixed temporary bridge during&#xd;
the healing of permanent implants was evaluated in 45 patients with either partially (19 patients) or totally (26&#xd;
patients) edentulous maxillae. The patients were followed from implant surgery to abutment connection of the&#xd;
permanent implants. Paper II. The primary implant stability of 905 implants in 267 consecutive patients treated&#xd;
with implant-supported fixed prostheses was assessed using resonance frequency analysis (RFA) measurements&#xd;
(implants stability quations, ISQ) at implant placement surgery. The results were correlated with parameters&#xd;
related to the patient, implant site and the implant components. Paper III. A total of 96 patients were evaluated&#xd;
for immediate loading of implant-supported bridges in the posterior mandible (insertion torque &amp;gt; 30 Ncm, ISQ &amp;gt;&#xd;
60). 77 patients (85%) met with the criteria and a total of 257 implants were placed, 77 with a turned and minimally&#xd;
rough surface and 180 with an oxidized and moderately rough surface. A total of 111 FPDs were made. The&#xd;
bridges were supported by one implant and tooth or were freestanding constructions supported by 2, 3 or 4 implants.&#xd;
The patients were followed for at least one year with clinical and radiographic examinations. Paper IV.&#xd;
Twenty (20) patients treated with immediately loaded implant-supported bridges in the edentulous maxilla participated&#xd;
in the study group. Inclusion criteria for immediate loading were a minimum insertion torque of 30 Ncm&#xd;
and an implant stability value of 60 ISQ for the two posterior fixtures and a total sum of 200 (mean ISQ 50) for&#xd;
the four anterior fixtures was required. A group of 20 patients previously treated with implant-supported bridges&#xd;
in the maxilla by the same team following a two-stage protocol was used as a reference group. The patients were&#xd;
followed for one year with clinical and radiographic examinations. Paper V. A total of 115 one-piece implants&#xd;
(OPIs) with a moderately rough surface all the way up through the mocosa, were placed in 48 patients for immediate&#xd;
loading of single crowns and partial bridges in the mandible and the maxilla. A group of 97 patients previously&#xd;
treated by the same team under identical conditions with 380 two-piece implants (TPIs) for immediate&#xd;
loading was used as a control group. The patients were followed for one year with clinical and radiographic examinations.&#xd;
Results: Paper I. Seven (3.6%) PIs failed owing to infection or pain during the observation period and were removed.&#xd;
Seventeen (9%) of 192 provisional implants showed mobility at the second-stage surgery, although they&#xd;
had served as support for the provisional bridge without clinical symptoms during the follow-up time. Five (2.2%)&#xd;
of the 230 permanent implants placed did not integrate and were subsequently removed at the second-stage surgery.&#xd;
Paper II. The mean primary stability for the 905 implants was 67.4 ISQ (SD 8.6) where 582 (64.3 %) showed&#xd;
an ISQ value of 65 or higher and 761 (84.1%) implants an ISQ value of 60 or higher. Male patients showed higher&#xd;
ISQ values than females, mandibular implants were more stable than maxillary ones. Implants placed in posterior&#xd;
regions were more stable than in anterior sites, wide platform implants were more stable than regular/narrow&#xd;
platform ones. There was a correlation between bone quality and primary stability, with lower ISQ values with&#xd;
softer bone. A lower stability was seen with increased implant length. Paper III. A total of four (1.6 %) of the 257&#xd;
implants placed did not integrate and were subsequently removed. The overall cumulative survival rate was 98.4&#xd;
% after 1 year follow-up, 96.1% and 99.4 % for turned and oxidized implants, respectively. The average bone loss&#xd;
was 0.7 (S.D. 0.8) mm after one year of follow-up. Paper IV. One (0.8%) of 123 immediately loaded implants&#xd;
placed did not integrate. In the control group, no implants were lost. The overall cumulative survival rates after 1&#xd;
year were 99.2% for the study group and 100% for the reference group. The mean change of marginal bone level&#xd;
was 0.78 mm (SD 0.90 mm) for immediately loaded implants and 0.91 mm (SD 1.04 mm) for reference group&#xd;
implants. The differences were not significantly different. Paper V. Six OPIs (5.2%) were removed during the follow&#xd;
-up period because of extensive bone resorption and subsequent soft tissue problems. After 1 year, the mean&#xd;
marginal bone loss was 2.1mm (SD 1.3) for OPIs and 0.8mm (SD 1) for TPIs. 20% of OPIs showed more than 3mm&#xd;
of bone loss compared with 0.6% for TPIs. When compensating for vertical placement depth, OPIs still showed a&#xd;
lower marginal bone level and thus more exposed threads than TPIs. Depending on the criteria used, the success&#xd;
rate for OPIs was 46.1% or 72.2% compared with 85% or 91.6% for TPIs.&#xd;
Conclusion: It is concluded that immediate loading of two-piece dental implants results in good clinical outcomes&#xd;
if high primary stability is achieved and a rigid splinting with well controlled occlusion is applied. Provisional&#xd;
implants can be used as support of a provisional bridge during submerged healing of permanent two-piece implants.&#xd;
Moreover, it is concluded that one-piece implants show more bone resorption and higher failure rates&#xd;
than two-piece implants after one year in function.&#xd;
Keywords: dental implants, immediate loading, clinical studies, radiography, implant stability, resonance frequency&#xd;
analysis.&#xd;
ISBN: 978-91-628-7346-2&#xd;
Correspondence: Pär-Olov Östman, Holmgatan 30, SE-79171 Falun, Sweden, e-mail: po@holmgatan.se</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">eng</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart" lang="en">I. Östman PO, Hellman M, Nilson H, Ericsson I. Provisional implants: a clinical prospective study in 45 patients, from implant placement to delivery of the final bridge.Clin Implant Dent Relat Res. 2004;6:142-9. ::pmid::15726848</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart" lang="en">II. Östman PO, Hellman M, Wendelhag I, Sennerby L.  Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006;19:77-83 ::pmid::16479765</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart" lang="en">III. Östman PO, Hellman M, Sennerby L. Immediate occlusal loading of implants in the partially edentate mandible. A prospective 1-year radiographic and 4-year clinical study. In press, Int J Oral Maxillofac Implants In press</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart" lang="en">IV. Östman PO, Hellman M, Sennerby L. Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S60-9. ::pmid::16137089</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart" lang="en">V. Östman PO, Hellman M, Albrektsson T, Sennerby L. Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a 1-year prospective clinical and radiographic study. Clin Oral Impl Res 18, 2007; 409-41. ::pmid::17501980</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">dental implants</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">immediate loading</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">clinical studies</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">radiography</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">implant stability</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">resonance frequency analysis</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">On various protocols for direct loading of implant-supported fixed prostheses</dim:field>
   <dim:field mdschema="dc" element="type" lang="eng">text</dim:field>
   <dim:field mdschema="dc" element="type" qualifier="svep" lang="eng">Doctoral thesis</dim:field>
   <dim:field mdschema="dc" element="type" qualifier="degree" lang="en">Doctor of Philosophy (Medicine)</dim:field>
   <dim:field mdschema="dc" element="gup" qualifier="mail" lang="en">po@holmgatan.se</dim:field>
   <dim:field mdschema="dc" element="gup" qualifier="defence" lang="en">Fredagen 21/12 2007, Kl 13.00 Avd Biomaterialvetenskap, Medicinare gatan 8B, 4 vån, Föreläsningssalen</dim:field>
   <dim:field mdschema="dc" element="gup" qualifier="origin" lang="en">Göteborg University. Sahlgrenska Academy</dim:field>
   <dim:field mdschema="dc" element="gup" qualifier="department" lang="en">Inst of Clincial Sciences. Dept of Biomaterials</dim:field>
   <dim:field mdschema="dc" element="gup" qualifier="dissdb-fakultet">SA</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>