Title: Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies
Authors: Shareghi, Bita
E-mail: bita.shareghi@vgregion.se
Issue Date: 19-Jan-2018
University: University of Gothenburg. Sahlgrenska Academy
Institution: Institute of Clinical Sciences. Department of Orthopaedics
Parts of work: I. Shareghi B, Johanson PE, Kärrholm J. Femoral Head Penetration of Vitamin E-Infused Highly Cross-Linked Polyethylene Liners: A Randomized Radiostereometric Study of Seventy Hips Followed for Two Years. J Bone Joint Surg Am. 2015 Aug 19;97(16):1366-71.
VIEW ARTICLE


II. Shareghi B, Johanson PE, Kärrholm J. Wear of Vitamin E-Infused Highly Cross-Linked Polyethylene at Five Years. J Bone Joint Surg Am. 2017 Sep 6;99(17):1447-1452.
VIEW ARTICLE


III. Shareghi B, Johanson PE, Kärrholm J. Clinical evaluation of model-based radiostereometric analysis to measure femoral head penetration and cup migration in four different cup designs. J Orthop Res. 2017 Apr;35(4):760-767.
VIEW ARTICLE


IV. Shareghi B, Mohaddes M, Kärrholm J. Pelvic tilt between supine and standing after total hip arthroplasty. 106 patients examined with RSA up to seven years after the operation. In manuscript.

V. Migration of uncemented cups and development of radiolucent lines. Ra- diostereometric evaluation of 92 cups with either porous titanium or plas- ma sprayed surface coating up to ve years. In manuscript.
Date of Defence: 2018-02-09
Disputation: Fredagen den 9 februari 2018, kl.9.00, R-aulan, Sahlgrenska Universitetssjukhuset, Mölndal
Degree: Doctor of Philosophy (Medicine)
Publication type: Doctoral thesis
Keywords: Total hip arthroplasty
Radiostereometry
Femoral head penetration
Highly cross- linked polyethylene
Polyethylene wear
Radiolucent lines
Pelvic tilt angle
Abstract: Total hip arthroplasty (THA) aims to relieve pain, increase hip function and improve quality of life for patients with end- stage osteoarthritis of the hip who do not benefit from non-surgical treatment. Despite constant improvements in prosthetic component design and surgical techniques, prosthetic loosening, wear and dislocation remain the most common complications of a hip replacement procedure. Roentgen Stereophotogrammetric Analysis (RSA) is a highly accurate technique that enables three-di... more
ISBN: 978-91-629-0378-7 (print)
978-91-629-0379-4 (pdf)
URI: http://hdl.handle.net/2077/54196
Appears in Collections:Doctoral Theses from Sahlgrenska Academy
Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
Doctoral Theses / Doktorsavhandlingar Institutionen för kliniska vetenskaper

 

 

© Göteborgs universitet 2011