Show simple item record

dc.contributor.authorWright, Thomas
dc.date.accessioned2012-05-24T12:33:02Z
dc.date.available2012-05-24T12:33:02Z
dc.date.issued2012-05-24
dc.identifier.isbn978-91-628-8491-8
dc.identifier.urihttp://hdl.handle.net/2077/28959
dc.description.abstractAims: The aim of this thesis was to investigate the use of objective methods for the analysis of visual electrophysiological recordings. Specifically can signal identification algorithms identify electrophysiological signals and can they be applied to improve clinical testing and analysis? Methods: Automated signal identification algorithms were applied to multifocal electroretinogram (mfERG) and visual evoked potential (VEP) recordings. To simulate the types of signal identification problems encountered in the clinical environment, recordings were performed on healthy volunteers then artificially modified to represent the effects of disease. A multivariate analysis, spatial-temporal partial least squares (st-PLS) was applied to mfERGs recorded from a population of patients with Type 1 diabetes. Results: Signal identification algorithms were able to identify mfERG and VEP responses that had been artificially attenuated. The best performing algorithms outperformed human expert observers at identifying preserved mfERG responses. Application of signal detection algorithms increased the quality and reduced the time for recording VEPs. Metrics of algorithm performance demonstrated that algorithms using more prior knowledge about expected waveform morphology performed better than algorithms that were naive. Changes to retinal function in patients with Type 1 diabetes, measured using the mfERG, were detected using st-PLS analysis. The st-PLS analysis revealed information about the spatial and temporal distribution of these changes that was not revealed using traditional analysis methods. Conclusions: The application of more advanced analytical techniques can increase the accuracy and decrease the time required for clinical testing. Multivariate analysis techniques can reveal novel information about disease etiology.sv
dc.language.isoengsv
dc.relation.haspartWright T, Nilsson J, Gerth C, Westall C. A comparison of signal detection techniques in the multifocal electroretinogram. Doc Ophthalmol. 2008;117(2):163-70.::PMID::18324429sv
dc.relation.haspartWright T, Nilsson J, Westall C. Isolating Visual Evoked Responses Comparing Signal Identification Algorithms. Journal of Clinical Neurophysiology. 2011;28(4):404.::PMID::21811132sv
dc.relation.haspartWright T, Cortese F, Nilsson J, Westall C. Analysis of multifocal electroretinograms from a population with type 1 diabetes using partial least squares reveals spatial and temporal distribution of changes to retinal function. Doc Ophthalmol. In Press.sv
dc.subjectVisual Electrophysiologysv
dc.subjectSignal detectionsv
dc.subjectSignal-to-Noise Ratiosv
dc.subjectmultivariate analysissv
dc.subjectspatial-temporal partial least-squaressv
dc.titleSignal identification for visual electrophysiological recordings. A comparison of signal analysis techniques and their application to clinical electrophysiology of vision.sv
dc.typetexteng
dc.type.svepDoctoral thesiseng
dc.gup.mailthomas.wright@sickkids.casv
dc.type.degreeDoctor of Philosophy (Medicine)sv
dc.gup.originUniversity of Gothenburg. Sahlgrenska Academysv
dc.gup.departmentInstitute of Neuroscience and Physiology. Department of Clinical Neuroscience and Rehabilitationsv
dc.gup.defenceplacehörsal "Förmaket", Vita stråket 12, Sahlgrenska universitetessjukhuset, Göteborg, torsdagen den 14 juni 2012 kl 13.00sv
dc.gup.defencedate2012-06-14
dc.gup.dissdb-fakultetSA


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record